Hydraulic System Design and Sizing
- Home
- >
- Hydraulic Systems
- >
Hydraulic System Design and Sizing
From the machine cycle to the definition of actuators, power unit, circuit, control and fluid management
Designing a hydraulic system means translating the performance required by the machine into a solution in which forces, speeds, pressures, flow rates, power, control and operating conditions are consistent with one another. The starting point is therefore not the choice of pump or power unit, but the analysis of the application: which movements must be performed, with which loads and speeds, in what sequence, with what level of precision and under which environmental conditions.
From these data, the system is progressively defined: actuators, flow generation, distribution, control, energy storage, filtration, thermal management, sensors, safety devices and on-machine piping. Fluid System approaches this activity using an integrated design approach, with the ability to develop power units and cylinders in-house and complete the system through to connections and commissioning.
MACHINE FUNCTION
Loads · Movements · Timing · Precision
OPERATING CYCLE
Actuators and hydraulic functions
Pressure and flow rate over time
HYDRAULIC ARCHITECTURE
Generation · Distribution · Control
Filtration · Thermal management · Sensors · On-machine piping
VERIFICATION · TESTING · COMMISSIONING
Conceptual diagram 1 – From machine requirements to the hydraulic system.
1. Before sizing: define the machine cycle
A maximum pressure or flow-rate value, considered in isolation, describes only part of the application. To size the system correctly, it is necessary to know when that requirement occurs, for how long, and together with which other functions.
| Application data | Main impact on the design |
|---|---|
| Required forces and torques | Actuator selection and sizing. |
| Strokes and rotations | Required fluid volume and actuator configuration. |
| Movement speed | Required flow rate. |
| Sequence of operations | Pressure and flow-rate profile over time. |
| Simultaneous operation of functions | Flow rate and power required from the generation system. |
| Cycle frequency | Energy and thermal demand. |
| Precision and dynamic performance | Type of regulation, valves, feedback and control. |
| Environmental conditions | Materials, protection, cooling and any specific requirements or certifications. |
| Available space | Power-unit, piping and component layout. |
| Fluid | Component compatibility and filtration conditions. |
| Safety requirements | Architecture, protection devices and control logic. |
| Maintenance requirements | Accessibility, diagnostics and component arrangement. |
This analysis helps avoid two opposite errors: undersizing the system for the most demanding conditions, or oversizing it by assuming that demands which are not simultaneous in the actual machine occur at the same time.
2. Force, pressure and actuator sizing
For a hydraulic cylinder, the fundamental theoretical relationship is:
F = p × A
- F = force.
- p = applied pressure.
- A = effective area.
This relationship immediately shows why pressure and actuator size cannot be defined independently.
In a single-rod cylinder, moreover, the effective area changes according to the direction of movement.
A1 = π × D2 / 4
Cap-end area
A2 = π × (D2 − d2) / 4
Rod-end annular area
…where D is the bore and d is the rod diameter. At the same pressure, therefore, the available force and cylinder behaviour differ in the two directions.
These values are theoretical. In the actual design, back pressure, friction, circuit pressure losses, dynamic load conditions and margins appropriate to the application must also be considered. Rod sizing must also consider buckling stability in relation to unsupported length, diameter and end conditions.

3. Actuator speed and required flow rate
Once the effective area has been established, the required speed determines the flow rate:
Q = A × v
- Q = volumetric flow rate.
- A = effective area.
- v = actuator speed.
Here too, the different phases of motion must be considered separately.
In a single-rod cylinder, for the same flow rate, extension and retraction speeds are not necessarily equal because the effective area changes.
Sizing a machine with multiple hydraulic functions requires a further step: determining which flow rates must actually be available at the same time.
Design principle
The power-unit flow rate is not automatically the sum of the maximum flow rates of all hydraulic functions.
If several actuators operate in sequence, their individual maximum demands do not occur at the same time. If two or more functions must operate simultaneously, however, the overlap becomes part of the sizing process.

4. Pressure and flow rate determine hydraulic power
Pressure and flow rate converge in the power required by the circuit.
With pressure in bar and flow rate in litres/minute:
Ph = Δp × Q / 600
- Ph = theoretical hydraulic power in kW.
- Δp = pressure difference in bar.
- Q = flow rate in l/min.
The required electrical power is higher than the useful hydraulic power because energy transfer occurs with efficiencies lower than unity.
Pe ≈ Ph / η
where η represents the overall efficiency considered between the absorbed electrical power and the useful hydraulic power at the chosen reference point, taking into account component efficiencies and relevant system losses.
Power, therefore, should not be viewed solely as a maximum value: it is useful to represent its trend during the cycle to understand how long and how frequently the most demanding conditions are actually required.
Verified educational example
Bore = 80 mm; theoretical pressure = 160 bar; cap-end speed = 0.10 m/s.
Cap-end area ≈ 5,027 mm².
Theoretical force ≈ 80.4 kN.
Required flow rate ≈ 30.2 l/min.
Theoretical hydraulic power ≈ 8.0 kW.
This example serves exclusively to show the relationship between variables. It does not include friction, back pressures, efficiencies, dynamic conditions, design margins or structural checks.

5. From machine demand to the hydraulic power unit
Once pressure, flow rate and the cycle energy profile have been defined, the method for generating and managing hydraulic power can be established. The power unit is not merely the motor-pump assembly. It is a system in which the following elements must operate consistently:
| Element | Aspects to be defined |
|---|---|
| Pump | Flow rate, pressure, technology, operating range and control. |
| Motor | Power, torque, duty cycle, drive method and supply voltage. |
| Reservoir | Usable volume, return flows, thermal behaviour, degassing and overall dimensions. |
| Filtration | Required cleanliness level and pressure losses introduced. |
| Heat exchange | Heat load to be dissipated and environmental conditions. |
| Accumulators | Function, usable volume, pressures and operating method. |
| Distribution | Direction, pressure and flow rate to be controlled. |
| Instrumentation | Measurement, diagnostics and supervision. |
The correct configuration depends on the entire system.
Nota tecnica
Do not adopt a fixed ratio between reservoir volume and pump flow rate as a universal rule. Empirical ratios may be useful as a first approximation in specific contexts, but they do not replace verification of the cycle, thermal balance and actual configuration.
6. Selecting the circuit architecture
Once hydraulic power has been generated, it is necessary to determine how it will be distributed and controlled. The architecture depends on the required function, not on the sophistication of the technology.
| Machine requirement | Design elements to be assessed |
|---|---|
| Movements between defined positions | Directional control, sequences and safety conditions. |
| Speed control | Flow control and load influence. |
| Pressure control | Stability and behaviour during the different cycle phases. |
| Large variations in demand | Pump control or drive-speed control. |
| Temporary flow-rate peaks | Possible use of accumulators or variable-speed pumps. |
| Synchronisation | Feedback, sensors and coordinated control. |
| Positioning | Position measurement and control consistent with the required precision and dynamic performance (closed-loop control). |
| Load holding | Safety architecture and control at standstill. |
An on/off distribution system may be perfectly suitable for a simple function. When the machine requires continuous variation, controlled ramps, fine regulation or synchronisation, proportional technologies or more advanced control solutions may be necessary.
Selection criterion
The technically best solution is the one proportionate to the function to be performed, not necessarily the most complex one.
7. On-machine piping and pressure losses
System behaviour also depends on the elements connecting the components. Rigid pipes and flexible hoses, fittings, bends, valves, filters and other elements create resistance to fluid flow.
The pressure available at the actuator is therefore the upstream pressure generated by the system minus the losses along the flow path.
When sizing on-machine piping, the following must be considered:
- flow rate;
- internal diameter;
- length;
- fluid characteristics;
- temperature and viscosity;
- operating pressure;
- distributed and local pressure losses;
- pump suction conditions;
- transient phenomena;
- vibration;
- accessibility and maintenance.
An undersized line can increase fluid velocity, pressure losses (Δp) and heat generation. An unnecessarily oversized line can instead increase system dimensions, fluid volume and cost.
Piping is therefore part of system sizing, not merely a subsequent installation stage.
8. Filtration: controlling fluid contamination
Contamination control is not limited to solid particles. Hydraulic fluid may contain solid contaminants, water and air: three different forms of contamination, with different origins and effects, which must be considered from the system design stage.
Contamination may be introduced during filling, assembly or maintenance, enter from the external environment, or be generated during operation through component wear. Filtration, reservoir ventilation, water control and proper bleeding are therefore not separate issues, but parts of overall fluid management.
| Type of contamination | Main origin and effects | Control criteria |
|---|---|---|
| Solid | Particles already present in the fluid or introduced during production, assembly and maintenance; others may enter from the environment or be generated by wear. They can cause abrasion, erosion, sticking, increased leakage and loss of component precision. | Hydraulic filtration appropriate to the circuit architecture; controlled filling and maintenance; limitation of ingress from the environment and monitoring of filter condition. |
| Water | It may be present in free or dispersed/emulsified form. It can enter during filling, from the reservoir or through moisture in the air. It promotes oxidation and corrosion and may alter fluid properties. | Protection of the reservoir from the environment; suitable air breather/vent filter; moisture control and, where necessary, dedicated water-separation or removal systems. |
| Air | It may be present in the system before commissioning or introduced during maintenance work. It can contribute to pump cavitation, vibration and control inaccuracies. | Properly positioned bleed points and bleeding procedures during commissioning and after work that may introduce air into the circuit. |
For solid contamination, ISO 4406:2021 defines the coding method for the level of particulate contamination in the fluid. The required cleanliness level must be established according to component sensitivity and system operating conditions.
The following must therefore be defined in a coordinated manner during design:
- required cleanliness level and contamination-control criteria;
- position of hydraulic filters – for example on the suction, pressure or return line – according to the system architecture;
- filtration rating, capacity relative to flow rate and allowable pressure losses;
- clogging monitoring and filter maintenance conditions;
- reservoir ventilation and protection against the ingress of contaminants and moisture;
- bleed points and procedures for removing air during commissioning and maintenance.
The selection must also consider fluid viscosity and temperature, start-up conditions, installation environment and component criticality. Filtration is therefore not an accessory added after the design has been completed, but a function that must be sized together with the system.
Conceptual example of possibile filtration positions

* Hydraulic-filter position and type depend on the system architecture. The reservoir air breather performs a separate function.
Conceptual diagram 3 – Example of possible filtration positions. The hydraulic filters marked with * are examples: their position and type depend on the system architecture. The air breather connected to the reservoir performs a function distinct from the filters in the liquid circuit.
9. Thermal balance: where unused energy goes
System pressure losses are converted into heat. Pumps, motors, throttling across valves, pressure drops in the piping and other dissipative phenomena contribute to an increase in fluid temperature.
heat generated ↔ system heat-dissipation capacity
Temperature, in turn, affects viscosity, seals, efficiency and component service life.
When natural heat dissipation through the reservoir, piping and surfaces is insufficient, a heat exchanger may need to be integrated.
The assessment must consider the actual cycle: a very short power peak and a continuously high power demand do not produce the same thermal behaviour.

10. Energy efficiency: matching machine demand
- fast movements at low pressure;
- high-pressure working phases;
- holding phases;
- deceleration phases;
- waiting phases;
- return movements under different loads.
- variable-displacement pumps;
- dedicated pressure and flow-control strategies;
- variable-speed drives;
- servo pumps;
- energy storage, where appropriate.
Energy principle
Generate the power required when it is required, rather than keeping maximum capacity available throughout the cycle.

11. Accumulators: more than a fluid reserve
Where used, accumulators must be sized according to the function they are required to perform.
Depending on the architecture, they may be used for:
- energy storage for safety or emergency functions;
- covering temporary flow-rate demands;
- maintaining a pressure condition;
- compensating for variations;
- damping pulsations.
Geometric volume, pre-charge, operating pressures and gas behaviour are interrelated. Accumulator sizing should therefore not be reduced to nominal capacity alone.
Isolation and safety devices must also be considered as part of the overall assembly.
Where applicable, gas-charged hydraulic accumulators fall within the scope of Directive 2014/68/EU (PED) on pressure equipment; classification, conformity assessment and safety devices must be verified according to the characteristics of the equipment and the application.
12. Sensors, control and diagnostics
In electrohydraulic systems, the hydraulic and control sections must be developed in a coordinated manner. Effective diagnostics and proper maintenance help prevent damage to the system.
Depending on the function, the system may use:
- pressure switches and pressure transducers;
- temperature sensors;
- level monitoring;
- position transducers on actuators;
- flow measurement;
- filter status signals;
- PLCs and supervisory systems.
Measurement is not used merely to display a value. It can become part of the machine function: measurement → processing → command/control → verification of the result.
Where required, this integration makes it possible to implement control, diagnostic and protection logic based on the conditions actually detected.
13. Safety: assessing behaviour under abnormal conditions
- overpressure;
- loss of power supply;
- line failure or leakage;
- unintended actuator movement;
- energy stored in accumulators;
- maintenance conditions;
- restarts;
- interaction between the hydraulic system and the control system.
Compliance note
The applicable legislation and standards must be identified for the specific project. The presence of certified components does not automatically imply compliance or certification of the complete system.
14. Verifying the system before commissioning
Sizing is complete when the behaviour of the overall system has been verified, not when the last component has been selected. Depending on the project, checks and testing may cover:
| Parameter | What it allows you to verify |
|---|---|
| Pressures | Correct management of loads and control settings. |
| Flow rates | Compliance with the required speeds and simultaneous operations. |
| Cycle times | Consistency with the required performance. |
| Temperatures | Adequacy of thermal behaviour. |
| Sequences | Correct interaction between hydraulic functions. |
| Sensors | Consistency between the measured value and control logic. |
| Leak-tightness | Circuit integrity. |
| Safety functions | Response to the conditions defined in the design and in the hydraulic-system risk analysis. |
Factory testing makes it possible to complete all the checks that can be carried out before delivery. Commissioning on the machine then allows final adjustments and checks to be completed under actual operating conditions.
From design principle to real application
The cases below are intentionally brief: their purpose is to link a technical criterion to a real application.
The full content is available in the “Case Studies” section.
APPLICATION CASE
In this application, the hydraulic system was developed to actuate slide gates in a plant subject to specific environmental conditions and certification requirements.
The power-unit configuration, materials and components were therefore selected on the basis not only of pressure and flow rate but also of the installation environment, operational continuity and the requirements of the complete assembly.
APPLICATION CASE
For a shiploader system designed to move the tilting chute, Fluid System developed a hydraulic assembly in which the power units, position-controlled cylinders, distribution and components were defined according to the required movement and the environmental conditions of the installation.
The project also had to meet the specific requirements for operation in a hazardous area: an example of how performance, control, environment and compliance must be considered together from the architecture definition stage.
One decision affects the others
One of the essential characteristics of a hydraulic system is the interdependence of design choices.
Increasing the speed required from an actuator changes the flow rate. Changing the flow rate affects pump sizing, piping and pressure losses (Δp). These, in turn, affect efficiency and thermal balance. Changing the control architecture may further change energy demand, temperature and dynamic behaviour.
For this reason, correct sizing cannot be carried out by considering components in isolation.

Fluid System technical resources
Hydraulic Systems
The integrated solution: power unit, actuators, distribution, piping and commissioning.
Hydraulic Power Units
Production of special, standard, modular and high-efficiency power units.
Hydraulic Cylinders
Special, ISO and welded cylinders designed and manufactured in-house.
Servo pumps
Technologies for variable-demand hydraulic power generation.
Technical Service
Maintenance, service work and system support.
Case Studies
Fluid System applications developed for specific industrial requirements.
Do you need to design a hydraulic system?
Forces, speeds and pressures are only part of the challenge. Machine cycle, simultaneous operation of functions, control, thermal management, piping and installation conditions can significantly affect the solution. Fluid System develops complete hydraulic systems starting from the machine’s actual requirements, through to testing and commissioning.
Request techical support.
FAQ Hydraulic system design and sizing
Start with the function required by the machine: loads, movements, speeds, strokes, times, simultaneous operations, precision, environment and operating conditions. These data are then translated into the hydraulic requirements of the system.
For a linear actuator, flow rate is related to effective area and required speed: Q = A × v, where Q is volumetric flow rate, A is the actuator effective area and v is linear speed. In systems with multiple functions, their actual simultaneous operation during the cycle must also be assessed.
As a first approximation, the required pressure is obtained from the ratio between the required force and the actuator effective area: p = F / A, where p is pressure, F is the required force and A is the effective area. In the actual design, back pressure, pressure losses, friction, dynamic conditions and the overall circuit characteristics must also be considered.
In theoretical terms, with pressure in bar and flow rate in l/min: Pₕ (kW) = Δp × Q / 600. Installed power sizing must then take efficiencies and the actual cycle behaviour into account.
There is no universal ratio that is valid for every system. Usable volume, return flows, thermal management, degassing, duty cycle, overall dimensions and the overall characteristics of the power unit must be assessed.
When flow and pressure demand changes significantly during the cycle, variable-speed generation can make it possible to match the generated power more closely to actual demand. Its suitability must be assessed for the specific application.
Because they reduce the pressure actually available to the hydraulic functions and convert part of the energy into heat. Piping, fittings, valves and filters must therefore be included in the overall assessment.
According to component sensitivity, operating conditions and the cleanliness level required by the system. Particulate contamination can be expressed using the ISO 4406 coding system.
The power unit generates and manages hydraulic power. The complete system also includes actuators, distribution, control, piping, sensors and all the elements required to perform the function demanded by the machine.
No. These are important data, but they do not on their own describe the cycle, load duration, simultaneous operation, thermal behaviour, dynamics, precision and environmental conditions of the application.