CASE STUDY

Design and Construction of 4 ATEX/IECEx-Certified Hydraulic Power Units for Industrial Silo Slide Gates

centrale oleodinamica atex interno 024

Application goal

fuidsystem-icone-caso-studio

Sector and function

The power units were developed to operate slide gates (knife gate valves) on industrial silos located in zones classified as potentially explosive.

fuidsystem-icone-caso-studio

Customer requirements

The main requirement was the exclusive use of ATEX/IECEx-certified electrical components to ensure maximum operational safety in hazardous environments.

1

Design and components

Key components selected

System performance

Thermal management and filtration

2

Innovation and customization

Tailored Solutions

– Compact footprint, defined in collaboration with the client to fit the available installation space.
– Customized labeling, to simplify installation and maintenance procedures.

Challenges and Solutions

Component selection required special attention:
– Siemens/Innomotics special electric motors, for ATEX/IECEx compliance.
– ATOS solenoid valves, a leading brand in components for classified areas.

Distinctive Features Compared to a Standard Power Unit

– Use of ATEX/IECEx-certified electrical components.
– AISI-316 tank with protective coating for extreme environmental conditions.
– ATEX/IECEx-marked AISI-316 junction box.

valvole atex.jpg
centrale oleodinamica atex interno 03.jpg

3

Control, maintenance, safety

Sensors and Monitoring Devices

– 2 ATEX/IECEx level switches.
– 1 ATEX/IECEx PT100 probe (4-20 mA), for temperature monitoring.

Diagnostics and Accessibility

– While no digital predictive systems are implemented, the installed sensors provide essential monitoring data.
– All units are designed with easy access to main components, such as filter cartridges, to simplify routine maintenance.

Regulatory Compliance

– The power units are classified as “partly completed machinery” under the Machinery Directive 2006/42/EC, with incorporation declaration (Annex II1B).
– Design and construction in accordance with UNI EN ISO 4413, the reference standard for hydraulic systems and components.
– Electrical components are selected in compliance with ATEX/IECEx certification, an internationally recognized voluntary standard for use in hazardous areas.

4

Conclusion

This project—entirely managed, designed, and delivered by Fluid System—represents a successful integration of explosion-proof safety requirements, customized engineering, and reliable technical solutions. The four ATEX/IECEx-certified hydraulic power units provide an effective response to both environmental and regulatory challenges in the industry, while maintaining high standards of quality and reliability.

centrali oleodinamiche atex chiuse

Do you have a project to develop?

Request direct contact and speak with our experts.

With more than 40 years of experience — both in direct manufacturing and in technical distribution — we provide bespoke, efficient and high-performance solutions.

Contact us now for a free consultation and find out how to optimise your system!

    Read the privacy notice on the processing of personal data

    Scroll to Top